Sold

50 KW TOCCO MODEL 50-3T-O/H VACUUM INDUCTION BRAZING FURNACE

FURNACE
Manufacturer:
TOCCO
Model:
50-3T-O/H
Year:
1988
Stock #:
5136
50 KW TOCCO MODEL 50-3T-O/H VACUUM INDUCTION BRAZING FURNACE

Size 50 KW, 3KHz
In - 480 VAC + 10%, 65A, 30, 60 Hz, 58 KVA (1) *
Out - 50 KW, 400V, 139A, 10, 3 KHz, .90 pf min.
Water
Maximum inlet temperature allowable 90 deg. F (35 deg. C)
Minimum inlet temperature allowable above dew point
Minimum inlet pressure 30 PSI (differential inlet to outl
et)
Maximum system pressure 100 PSI
Maximum outlet water temperature individual lines or combinati
on 140 deg.
F (60 deg.
C)
Absolute minimum allowable resistivity of water 2,200 ohm cm
Air
Maximum ambient air temperature 125 deg. F (52 deg. C)
Remote Meter Panel
All meter wires are to be twisted pairs or twisted shielded wi
re grounded at one
point only. Use 16 or 18 ga. wire 600V insulation.
Control potentiometer(s) must be twisted wires or twisted shie
lded cable grounded
at one point only.
Use 16 or 18 ga. wire, 600V insulation.
All wires for meter panel lights, switches, meters, and contro
l potentiometers must
be run in its own separate conduit.
Output
All output Hf cables should be inter-posed to reduce impedance
and power losses.
All output Hf cables should be run in non-ferrous non-magnetic
conduit or tray
to prevent induction heating of conduit or tray.
(CONT.)
General
No additional timers, relays, or lights are to be connected to
the inductron's
control transformer.
No additional timers, relays, or lights are to be mounted in t
he inductron cabinet
or meter panel without prior approval by the Tocco R & D
department.
Maximum altitude 6,000 ft. Notify Tocco R & D if requirements
exceed this
value.
TWO (2) PORTABLE WORK STATIONS, OL-68 SERIES
The OL-68 Work Station is a steel enclosure designed to house and cool the e
lectrical components
which convey high frequency power to an inductor. The construction of the c
abinet permits
mounting in any position.
Standard Specifications
Freq. kHz Volts K
var
Capacitor (one unit) 10 220
230
440
300
800
300
3 400
300
800
300
Output Vertical bus stud
Auxiliary Components
Pressure gauge (0 to 100 PSI, internal)
Interlocks (110 V, 15 A, 60 hz)
Differential pressure switch (Factory set to close at 30 PSI)
Door switch
Water Strainer
Closed drain (external - vertical or horizontal)
Page 3 of 3
(CONT.)
OPTIONS
OL-68-1 Transformer Output (variable or fixed ratio)
Horizontal output of OL-68 and OL-68-1
Autotransformer with or without tap switch Combination 1 of 2 with
bus stud output
only. With transformer output a penthouse is required.
Open sight drain (external) Individual sight of water cooling from
inductor, capacitor,
bus and transformer if supplied. Provided with standard press
ure switch.
PORTABLE WORK STATION, OL-68 SERIES
Two capacitors Vertical bus stud or transformer
Freq. kHz Volts K
var
Capacitors 10 440
450
800
450
3 400
450
800
450
Water Cooling
Flow (exclusive of Inductor) OL-68-1 (9 gpm)
Pressure (30 to 90 PSI)
Hardness (12 grains/gallon maximum)
Inlet temperature
Maximum (90 deg. F)
Minimum (Select to avoid condensation)

OL-245-1 Water recirculator, 50 GPM, 7-1/2 HP Pump motor
Two (2) Varian SD-1400 vacuum pumps
Two (2) Pyrex bell jars BG18x18
Allen Bradley programmable controllers SLC-100